Characteristics
Signal Acquisition System
Bandwidth -
TDS210: 60 MHz
TDS220: 100 MHz
TDS240: 100 MHz
Sample Rate - 1 GS/s on each channel
Channels -
TDS210 and TDS220: 2 identical channels plus external trigger
TDS224: 4 identical channels
Sensitivity (with calibrated fine adjustment) - 2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 mV/div and 5 mV/div, in all modes, and 20 MHz at 10 mV/div in Peak Detect mode)
Vertical Zoom - Vertically expand or compress a live or stopped waveform
Calibrated Position Range
Volts/Div Setting |
Offset Range |
---|---|
2 mV to 200 mV/div |
±2 V |
>200 mV to 5 V/div |
±50 V |
DC Gain Accuracy - ±3% (±4% at 2 mV/div and 5 mV/div)
Vertical Resolution - 8-bit (256 levels over 10.24 vertical divisions)
Automatic Measurements
Period, frequency, cycle RMS, mean, peak-to-peak
Acquisition Modes
Sample, Average, Peak Detect - High frequency and random glitch capture; captures glitches as narrow as 10 ns using acquisition hardware at all time/div settings between 5 µs/div and 5 s/div
Time Base System (main and Window)
Horizontal Zoom - Horizontally expand or compress a live or stopped waveform
Time/Division Range - 5 ns to 5 s/div
Record Length - 2,500 sample points per channel
Horizontal Accuracy - ±0.01%
Nonvolatile Storage
Waveform Display - Two 2,500 point reference waveforms
Waveform Storage -
TDS210 and TDS220: Two 2,500 point reference waveforms
TDS224: Four 2,500 point reference waveforms
Setups - 5 front panel setups
Triggering System (main Only)
Trigger Type - Edge (rising or falling), video, set to 50%
Video Trigger Type - Triggers on fields or lines from composite video; triggers on broadcast standard NTSC, PAL or SECAM video
Trigger Modes - Auto, normal, single sweep
Trigger Source -
TDS210 and TDS220: CH1, CH2, Ext, Ext/5 and AC Line
TDS224: CH1, CH2, CH3, CH4 and AC Line
Trigger View - Displays trigger signal while trigger view button depressed.
Cursors
Types - Voltage, time
Measurements - Delta T, 1/Delta T, Delta V
Waveform Processing
Arithmetic Operators - Add, subtract
Sources - CH1±CH2, CH3±CH4 (TDS224)
Autoset - Single button automatic setup on selected input signal for vertical, horizontal and trigger systems.
Display System
Robust, backlit LCD with adjustable multilevel contrast.
Interpolation - Sin(x)/x
Display Modes - Vectors, dots
Persistence - Off, 1 sec, 2 sec, 5 sec, infinite
Format - YT and XY
Hardcopy Capability (requires Modules)
Printer/File Formats - Thinkjet, Deskjet, Laserjet, Epson (9- or 24-Pin), BMP, PCX, IMG, EPS, DPU 411, DPU 412
Hardcopy Layout - Landscape or portrait
TDS2CM Communications Extension Module
Centronics-type Parallel Port
RS-232 Programmability - Full talk/listen modes. Control of all modes, settings and measurements. Baud rate up to 19,200. 9-Pin, DTE.
GPIB Programmability - Full talk/listen modes. Control of all modes, settings and measurements (IEEE Std 488-1987). Includes WaveStar™ Software for Oscilloscopes 30 day product demo.
TDS2MM Measurement Extension Module
FFT -
Windows: Hanning, Flat Top, Rectangular
Sample points: 2,048
Automatic Measurements - Rise/fall time, positive/negative pulse width
Interface - Centronics, RS-232, GPIB
Environmental and Safety
Temperature -
Operating: 0°C to +50°C
Nonoperating: -20°C to +60°C
Humidity -
Up to 90% RH at or below +40°C;
Up to 60% RH from 41°C to 50°C (operating and nonoperating)
Altitude - Up to 3,000 m (operating)
EMC - Meets Directive 89/336/EEC, GOST
Safety - UL3111-1, CSA1010.1, IEC61010-1, EN61010-1
Physical Characteristics
Dimensions |
mm |
in. |
---|---|---|
Weight |
kg |
lb. |
Width |
304.8 |
12.0 |
Height |
151.4 |
5.96 |
Depth |
120.7 |
4.75 |
Oscilloscope only |
1.5 |
3.25 |
w/accessories |
1.7 |
3.75 |