What is included in the 4200A-SCS Windows 10 Upgrade option?

Subject: Products | Published: October 2026 | FAQ ID: KB-01254

Question: What is included in the 4200A-SCS Windows 10 Upgrade option? Answer: The 4200A-SCS can be upgraded from the Windows 7 operating system to Windows 10. The part number for this...

Viewing expanded preview


Question: What is included in the 4200A-SCS Windows 10 Upgrade option?

Answer: The 4200A-SCS can be upgraded from the Windows 7 operating system to Windows 10. The part number for this upgrade is 4200A-WIN10-UP.
This service will provide a USB flash drive containing the upgrade program files and instructions for installing the upgrade.

 

This FAQ Applies to:

Product Series: Keithley 4200A-SCS Parameter Analyzer

What is enhanced security option MDO4SEC on the MDO4000C?

Subject: Products | Published: October 2026 | FAQ ID: KB-01439

Question: What is enhanced security option MDO4SEC on the MDO4000C? Answer: Option MDO4SEC add’s enhanced instrument security to enable password protected control of turning on/off all instr...

Viewing expanded preview


Question: What is enhanced security option MDO4SEC on the MDO4000C?

Answer: Option MDO4SEC add’s enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality. It is a one-time permanent upgrade.

Product Series: MDO4000C Mixed Domain Oscilloscope

What PC should I get to work with the RSA306?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-01895

Question: What PC should I get to work with the RSA306 and all USB RSAs Models? Answer: Any PC that meets the performance requirements should work.  Tektronix doesn’t make a specific re...

Viewing expanded preview


Question: What PC should I get to work with the RSA306 and all USB RSAs Models?

Answer: Any PC that meets the performance requirements should work.  Tektronix doesn’t make a specific recommendation, but a list of models we’ve evaluated is shown below.  In one case, we’ve found an Intel core i5-based tablet (Surface 3 Pro) that does meet minimum signal duration specifications.

ManufacturerModelProcessorMeets minimum signal duration specification?Meets streaming data requirement?
Dell  XPS15-6842sLVIntel corei7-4702HQ 2.2GHzYesNo (spin drive)
Lenovo  Yoga 2 ProIntel corei7-4500U 1.8GHzYesNo (spin drive)
MicrosoftSurface 3 ProIntel core i7-5650U @ 1.7-2.3 GHzYesYes (Solid-state drive)
MicrosoftSurface 3 ProIntel corei5-4300U CPU @ 1.7-2.5 GHzYesYes (Solid-state drive)
Motion ComputingF5teIntel core i7-3667 CPU @ 2.00 GHz YesYes  (Solid-state drive)
ToshibaSatellite s55t-BIntel Core i7-4710HQ 2.5GHzYesNo (spin drive)
LenovoThink PadIntel corei7 3632QM 2.2 GHzYesNo (spin drive)

 

Product Series: RSA306B USB Spectrum Analyzer RSA500 Series Real Time Spectrum Analyzers RSA600 Series Real Time Spectrum Analyzers

What feature does the DPO4BND included?

Subject: Products | Published: October 2026 | FAQ ID: KB-01446

Question: What feature does the DPO4BND included? Answer: DPO4BND includes the features for the following modules.  DPO4AERODPO4AUDIO DPO4AUTODPO4COMPDPO4EMBDDPO4ENETDPO4LMTDPO4PWR...

Viewing expanded preview


Question: What feature does the DPO4BND included?

Answer: DPO4BND includes the features for the following modules.

  •  DPO4AERO
  • DPO4AUDIO
  •  DPO4AUTO
  • DPO4COMP
  • DPO4EMBD
  • DPO4ENET
  • DPO4LMT
  • DPO4PWR
  • DPO4USB
  • DPO4VID

Note: Compatibility Issues below:

  •  The DPO4BND application module is compatible with all MDO/MSO/DPO4000B/C and MDO4000 series instruments.
  •  The DPO4BND application module is NOT compatible with the MSO/DPO4000 non-B Series.
  • The DPO4BND requires firmware version 3.18 or greater for instrument compatibility.

Product Series: MDO4000C Mixed Domain Oscilloscope MSO/DPO4000 Mixed Signal Oscilloscope (Discontinued)

What communication ports are available on the AFG3000 series?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-03242

Question: What communication ports are available on the AFG3000 series? Answer: The number and type of communication ports available vary with the model of AFG3000. AFG3021 and AFG3022 have...

Viewing expanded preview


Question: What communication ports are available on the AFG3000 series?

Answer: The number and type of communication ports available vary with the model of AFG3000.

  • AFG3021 and AFG3022 have a USB (B) port standard. This port is located on the rear panel. There is no option to add other types of ports
  • AFG3011, AFG3021B, AFG3022B, AFG3102, AFG3102, AFG3251, and AFG3252 have USB (B), GPIB, and LAN ports standard. All of these ports are located on the rear panel.
  • All AFG3000 series have a USB (A) port located on the front panel for memory stick usage.

Note: All port types use the same set of commands to control the AFG3000 series. These commands are covered in the Reference manual, which is provided standard as a PDF on the CD-ROM.

Product Series: AFG3000C Arbitrary/Function Generator AFG3000C Arbitrary/Function Generator AFG3000C Arbitrary/Function Generator AFG3000C Arbitrary/Function Generator AFG3000C Arbitrary/Function Generator AFG3000C Arbitrary/Function Generator AFG3000C Arbitrary/Function Generator

How do I get more retention posts for the P6960+ P6962+ P6964+ P6980 or the P6982?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-03918

Question: How do I get more retention posts for the P6960+ P6962+ P6964+ P6980 or the P6982? Answer: The replacement kit can be ordered with part number 020-2539-00. This kit contains one bl...

Viewing expanded preview


Question: How do I get more retention posts for the P6960+ P6962+ P6964+ P6980 or the P6982?

Answer: The replacement kit can be ordered with part number 020-2539-00. This kit contains one black post, one silver post, and two sets of mounting wires (long and short) for different PCB thicknesses.

 

How do I use the serial decoder function on the MDO3000?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-01916

Question: How do I use the serial decoder function on the MDO3000? Answer: The MDO3000 has the ability to decode bus data into binary, hexadecimal, decimal, or ASCII values depending on the...

Viewing expanded preview


Question: How do I use the serial decoder function on the MDO3000?

Answer: The MDO3000 has the ability to decode bus data into binary, hexadecimal, decimal, or ASCII values depending on the protocol. It will separate the decoded data into address, control, data, and clock information. In addition to decoding the signals, the MDO3000 can trigger on decoded content, including start of packet, specific addresses or data, unique identifiers, and more.

For this demo I’m looking at an I2C bus, with channel 1 acquiring the I2C clock and channel 2 acquiring the I2C data. I’ll change my record length to 1M points in order to reach the timing resolution necessary to decode the bus.

I can change my record length by pressing the Acquire button, pressing the Record Length softkey, and using the multipurpose knob A to change the record length. Let’s also change the horizontal scale to acquire more data and capture a single acquisition by pressing the Single button. To bring up the bus decode function, press the B1 button, press the Bus B1 softkey, and use the multipurpose knob A to select I2C. Press the Define Inputs softkey and make sure that the channels are assigned to the correct inputs.

Press the Thresholds softkey and set the thresholds using the multipurpose knob A for channel 1 and multipurpose knob B for channel 2. The threshold levels tell the scope the level above which should be decoded as a data 1 and below which is a data 0. You can now see the decoded bus values show up on the purple bus line in the middle of the screen. Zoom in on the decoded values using the inner Wave inspector knob and pan around using the outer wave inspector knob. You can see the Address bits bordered in yellow and the data bits bordered in blue. You’ll also notice that the start of packet is marked by a green bracket and the end of packet is marked by a red bracket.

To change the way the data is decoded, press the Bus Display softkey and toggle between Hexadecimal and binary with their respective softkeys. You can also use the Event Table to view all the decoded values in tabular form. Select the Event Table softkey and then select the Event Table On/Off button to toggle the Event Table. The multipurpose knob A can be used to scroll through and select events, all of which are time correlated, and the Event Table can be exported as a .csv file if an external drive is mounted.

To trigger on decoded information, go to the trigger menu, press the Type softkey and scroll down to Bus using multipurpose knob A. Press the Trigger On softkey and select Address using multipurpose knob A. Set the address value by pressing the Address softkey at the bottom of the screen, select the Address softkey on the side of the screen, and use multipurpose knob A to change the cursor position and use multipurpose knob B to change the value. I’m going to trigger when the scope sees an address of 50 hex. I can select the direction to write, read, or both using the Direction softkey. Now, whenever I press the Single acquisition button, the scope will trigger when it finds a 50 hex address. Notice the orange trigger arrow is right above the address.

You can also search for different decoded values within your acquisition. In this case, I want to see all the places that the bus sends a 50 hex address. Press the Search button, press the Search softkey, select the Search On/Off softkey to turn it on, and press the copy Trigger Settings to Search softkey. You can use the Wave inspector arrows to jump between instances of the search event. Much like the Event Table, you can use the Mark Table to view all the instances of the search event in tabular form. Press the -more- 1 of 2 softkey and press the Mark Table softkey to turn on the Mark Table

Instead of manually counting clocks, determining if a bit is a 1 or a 0, combining bits into bytes, and compiling all the information yourself, the MDO3000 will do it all for you. This is just one of the many useful features the MDO3000 brings to the test and measurement table.

 

For more information please see How do I use the serial decoder function on the MDO3000 

Product Series: MDO3000 Mixed Domain Oscilloscope

 

How do I find the IP address for a 2450-NFP (no front panel)?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-01377

Question: How do I find the IP address for a 2450-NFP (no front panel)? Answer: Your TCP/IP v4 settings should be set to obtain an IP address and DSN server dynamically (obtain address autom...

Viewing expanded preview


Question: How do I find the IP address for a 2450-NFP (no front panel)?

Answer: Your TCP/IP v4 settings should be set to obtain an IP address and DSN server dynamically (obtain address automatically). Connect a standard CAT 5 cable (not the yellow Cat 5 crossover cable) to between the computer and 2450. Do not connect to a hub or router when you do this. Be sure you are connecting to the Ethernet port, not the TSP link ports. Open the Command Prompt (found in the Accessories), type ipconfig. Look for the Ethernet adapter Local Area Connection and the address assigned to the TCP/IP v4 listing for the Local Area Connection. i.e. 169.254.152.51. From the Command Prompt, type arp -a. There will be a list of addresses that will be returned. The display should indicate an IP address that shares the first two numbers as your computer's Ethernet adapter local area connection.

Under the Type heading, the address type should show as dynamic. You can then go to your web browser by typing in that IP address. If the address is correct, you should get the 2450 web page for the instrument.

How do I enable Virtual CE (option VCE) on my Y400 NetTek?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-03923

Question: How do I enable Virtual CE (option VCE) on my Y400 NetTek? Answer: Once you have obtained the key string from Tektronix for Option VCE for the NetTek Y400 or Y350C, go to the Start...

Viewing expanded preview


Question: How do I enable Virtual CE (option VCE) on my Y400 NetTek?

Answer: Once you have obtained the key string from Tektronix for Option VCE for the NetTek Y400 or Y350C, go to the Start menu on the NetTek desktop. Select Programs, then select Communication, then select Virtual CE.
A Virtual CE Registration window will appear. Open the small keyboard icon and type in exactly (with dashes) the keycode that was provided. Then close the keyboard by pushing the keyboard icon again, and finally, select Next.

If you do not see the key registration screen, and instead see the Virtual CE screen, the option has previously been installed.

How do I check the IP address of my TLA (or any Windows 2000/XP computer)?

Subject: Setup & Operation | Published: October 2026 | FAQ ID: KB-03925

Question: How do I check the IP address of my TLA (or any Windows 2000/XP computer)? Answer: In Windows 2000 or Windows XP click on the "Start" button and select "Run". Type "cmd" in the box...

Viewing expanded preview


Question: How do I check the IP address of my TLA (or any Windows 2000/XP computer)?

Answer: In Windows 2000 or Windows XP click on the "Start" button and select "Run". Type "cmd" in the box and click "Ok". At the prompt, type "ipconfig" and press "Enter". It will now show you the IP address.

Product Series: TLA7000