Characteristics
General
Number of Channels (all channels are acquired including clocks) - TLA601/611/621: 34 channels (2 are clock channels).
TLA602/612/622: 68 channels (4 are clock channels).
TLA603/613/623: 102 channels (4 are clock and 2 are qualifier channels).
TLA604/614/624: 136 channels (4 are clock and 4 are qualifier channels).
Channel Grouping - No limit to number of groups or number of channels per group (all channels can be reused in multiple groups).
Time Stamp - 50-Bit at 500 ps resolution (6.5 day range).
Clocking/Acquisition Modes - Internal, internal 2X, external. 2 GHz MagniVu high-speed timing is available simultaneous with all modes.
Input Characteristics (with P6417, P6418 or P6434 probes)
Capacitive Loading - 1.4 pF typical data; 2 pF typical clock (P6418).
2 pF typical data and clock (P6417 & P6434).
Threshold Selection Range - From +5.0 V to -2.0 V in 50 mV increments.
Threshold Selection Channel Granularity - Separate selection for clock (1) and data (16) for each 17-Channel probe connector.
Threshold Accuracy (including probe) - ±100 mV.
Input Voltage Range - Operating: 6.5 Vp-p centered around the programmed threshold.
Non-destructive: ±15 V.
Minimum Input Signal Swing - 250 mV or 25% of signal swing, whichever is greater (P6417 & P6418).
300 mV or 25% of signal swing (P6434).
Input Signal Minimum Slew Rate - 200 mV/ns typical.
State Acquisition Characteristics (with P6417, P6418 or P6434 probes)
State Clock Rate - 100 MHz standard, 200 MHz optional.
State Data Rate (half/full channels) - 400/200 Mb/s, typical. Requires 200 MHz state option.
State Memory Depth with Timestamps - 64 Kb, 256 Kb, 1 Mb.
Setup Time Selection Range - From 8.5 ns before, to 7.0 ns after clock edge.
Setup-and-hold Window - 2.0 ns typical.
Minimum Clock Pulse Width - 2 ns.
Active Clock Edge Separation - 5 ns.
Demux Channel Selection - Channels can be demultiplexed to other channels through the user interface with 8-Channel granularity.
Timing Acquisition Characteristics (with P6417, P6418 or P6434 probes)
MagniVu™ Timing - 500 ps (2 GHz).
MagniVu Timing Memory Depth - 2 Kb per channel.
Deep Timing Resolution (half/full channels) - 2/4 ns to 50 ms.
Deep Timing Resolution with Glitch Storage Enabled - 10 ns to 50 ms.
Deep Timing Memory Depth (half/full channels with timestamps and with or without transitional storage) - 128/64 Kb, 512/256 Kb, 2/1 Mb.
Deep Timing Memory Depth with Glitch Storage Enabled - Half of default main memory depth.
Channel-to-channel Skew - ≤1 ns typical.
Minimum Recognizable Pulse/Glitch Width (single channel) - 2 ns.
Minimum Recognizable Multi-channel Trigger Event - Sample period +2 ns.
Trigger Characteristics
Independent Trigger States - 16.
Maximum Independent If/then Clauses per State - 16.
Maximum Number of Events per If/then Clause - 8.
Maximum Number of Actions per If/then Clause - 8.
Maximum Number of Trigger Events - 18 (2 counter/timers plus any 16 other resources).
Number of Word Recognizers - 16.
Number of Range Recognizers - 4.
Number of Transition Recognizers - 1.
Number of Counter/Timers - 2.
Trigger Event Types - Word, group, channel, transition, range, anything, counter value, timer value, signal, glitch, setup-and-hold violation.
Trigger Action Types - Trigger module, trigger all, store, don't store, start store, stop store, increment counter, reset counter, start timer, stop timer, reset timer, goto state, set/clear signal, do nothing.
Trigger Sequence Rate - DC to 250 MHz (4 ns).
Counter/Timer Range - 51 Bits each (>100 days at 4 ns).
Counter Rate - DC to 250 MHz (4 ns).
Timer Clock Rate - 250 MHz (4 ns).
Counter/Timer Latency - None (can be tested or reset immediately after starting).
Range Recognizers - Double bounded (can be as wide as any group, must be grouped according to specified order of significance).
Setup-and-hold Violation Recognizer Setup Time Range - From 8 ns before to 7 ns after clock edge in 0.5 ns increments.
Setup-and-hold Violation Recognizer Hold Time Range - From 7 ns before to 8 ns after clock edge in 0.5 ns increments.
Trigger Position - Any data sample.
MagniVu Trigger Position - MagniVu data is centered around the module trigger.
Storage Control (data qualification) - Global (conditional), by state (start/stop), by trigger action, or transitional.
Storage Window Granularity - Single sample or block-of-31 samples before and after.
Integrated View (iView) Capability
TLA mainframe configuration requirements - TLA6XX instruments.
TLA App S/W V 4.1 or greater.
256 MB DRAM Minimum, 512 MB recommended.
TDS configuration requirements - TDS3GM GPIB/RS232 Interface Module required for iView capability on any TDS3000 Series. TDS3GV GPIB/RS232/VGA Interface Module required for iView capability on any TDS3000B Series. If using iView with a TDS6604, order a TCA-BNC connector to be compatible with BNC cable run from a TLA7Axx module.
Number of TDS oscilloscopes that can be connected to a TLA system - 1.
External Oscilloscopes Supported - TDS3012, TDS3014, TDS3032, TDS3034, TDS3052, TDS3054.
TDS3012B, TDS3014B, TDS3032B, TDS3034B, TDS3052B, TDS3054B, TDS5052, TDS5054, TDS5104.
TDS6604.
TDS7054, TDS7104, TDS7154, TDS7404.
TDS684C, TDS694C.
CSA7154, CSA7404.
TDS754C, TDS784C, TDS724D, TDS754D, TDS784D, TDS794D.
TLA Connections - USB, Trigger In, Trigger Out, Clock Out.
TDS Connections - GPIB, Trigger In, Trigger Out, Clock In (when available).
Setup - iView external oscilloscope wizard automates setup.
Data Correlation - After TDS oscilloscope acquisition is complete, data is automatically transferred to the TLA and time correlated with the TLA acquisition data.
Deskew - TDS and TLA data is automatically deskewed and time correlated when using the iView external oscilloscope cable.
iView External Oscilloscope Cable Length - 2 m.

TLA600 Series with TDS3000 Series oscilloscope.
TLA600 PC Characteristics
Operating System - Microsoft Windows 2000 Professional.
Processor - Intel Celeron.
Chipset - Intel 810.
DRAM - 256 MB SDRAM.
Sound - Built-in PC speaker transducer; 16-Bit I/O and Mic In port.
Hard Disk Drive - 20 GB.
CD-ROM - Internal 16/8/32 CD-RW.
Floppy Disk Drive - Built-in 3.5 in. 1.44 MB drive.
TLA600 Integral Controls (TLA61x/62x only)
Front-Panel Display - Size: 10.4 in. diagonal.
Type: Active-matrix color TFT LCD with backlight.
Resolution: 800x600.
Colors: 16.8 M (true color).
Simultaneous Display Capability - The front-panel and external displays can be used simultaneously, each with independent resolutions.
Front-panel Knobs - Special function knobs for instrument control.
Front-panel QWERTY Keypad - Mini-QWERTY keypad.
TLA600 External Peripheral Interfaces
External Display Port Type - Female DB15 SVGA connector.
External Display Resolution - Up to 1280x1024 non-interlaced at 16 M colors.
LAN Port Type - 10/100Base-T, RJ-45.
External Keyboard Port Type - PS2 mini-DIN.
External Mouse Port Type - PS2 mini-DIN.
Parallel Interface Port Type - Female DB25.
Parallel Interface Modes - Centronics mode, EPP (Extended Parallel Port), ECP (Microsoft high-speed mode).
Serial Interface Port Type - Male DB9.
Audio Out Port Type - Stereo minijack.
Mic In Port Type - Minijack.
PC Card (CardBus) Slot Types - Two slots, two PC card type I/II or one PC card type III.
USB Port - One (1).
TLA60x Logic Analyzer with external
display.

TLA61x/62x
Logic Analyzer with internal display.
Symbolic Support
Number of Symbols/Ranges - Unlimited (limited only by amount of virtual memory available on TLA).
Object File Formats Supported -
- IEEE695
- OMF 51, OMF 86, OMF 166, OMF 286, OMF 386
- COFF
- Elf/Dwarf 1 and 2
- Elf/Stabs
- TSF (if your software development tools do not generate output in one of the above formats, TSF or the Tektronix symbol file, a generic ASCII file format is supported. The generic ASCII file format is documented in the TLA User Manual). If a format is not listed, please contact your local Tektronix representative.
External Instrumentation Interfaces
System Trigger Output - Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ohm).
System Trigger Input - Forces a system trigger (triggers all modules) when asserted (TTL-compatible, edge-sensitive, falling-edge latched).
External Signal Output - Can be used to drive external circuitry from a module's trigger mechanism (TTL-compatible output, back-terminated into 50 Ohm).
External Signal Input - Can be used to provide an external signal to arm or trigger any or all modules (TTL-compatible, level-sensitive).
Power
TLA60x/61x/62x - Voltage range/frequency: 90-250 VAC at 45-66 Hz.
100-132 VAC at 360-440 Hz.
Input current: 6 A maximum at 90 VAC (70 A surge).
Power consumption: 400 W maximum.
Physical Characteristics
|
TLA60x |
||
|---|---|---|
|
Dimensions |
mm |
in. |
|
Weight |
kg |
lb. |
|
TLA61x/62x |
||
|
Dimensions |
mm |
in. |
|
Weight |
kg |
lb. |
|
Height |
281.94 |
11.1 |
|
Width |
457.2 |
18 |
|
Depth |
414.02 |
16.3 |
|
Net (w/o probes) |
16.8 |
37 |
|
Shipping (typical) |
38.6 |
85 |
|
Height |
281.94 |
11.1 |
|
Width |
457.2 |
18 |
|
Depth |
414.02 |
16.3 |
|
Net (w/o probes) |
17.3 |
38 |
|
Shipping (typical) |
39.1 |
86 |

TLA60x Logic Analyzer with external display.

TLA61x/62x Logic Analyzer with internal display.
Environmental
Temperature - Operating: +5°C to +50°C.
Nonoperating: -20°C to +60°C.
Humidity - 20% to 80%.
Operating: ≤30°C; 80% relative humidity (29°C maximum wet bulb temperature).
Nonoperating: 8% to 80% (29°C maximum wet bulb temperature).
Altitude - Operating: -1,000 ft. to 10,000 ft. (-305 meters to 3,050 meters).
Safety - UL3111-1, CSA1010.1,
EN61010-1, IEC61010-1.
LACART
Instrument Cart (adjustable probe skyhook not shown).

K4000
Instrument Cart.