TLA7012 and TLA7016 Mainframe specifications

All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.

General characteristics
Instrument slots
TLA7012
Holds two TLA modules
TLA7016
Holds six TLA modules
Expansion capability
The TLA7000 Series mainframes can be used as either master or expansion mainframes (TL708EX 8-port Instrument Hub and Expander is required for 3-8 mainframes connected together using TekLink™ cable)
TLA7012
Up to eight TLA7012 mainframes can be used, providing support for up to 16 TLA modules (2,176 channels)
TLA7016
Up to eight TLA7016 mainframes can be used, providing support for up to 48 TLA modules (6,528 channels)
TLA7012 PC specifications
Operating system
Microsoft® Windows® 7 64-bit Ultimate
Processor
2.7 GHz i5 Processor
Chipset
Intel® QM77
Memory
Two (2) 4 GB DDR3 1600 MHz SODIMMs
Sound
Line In and Mic Out connectors
Removable hard drive
500 GB, 3.5 in, SATA II, 7200 RPM
Optical drive
Internal 4.7 GB DVD±R/RW
External display
One DVI (2048 x 1536); one HDMI (1920 x 1200); one VGA (2048 x 1200)
Network port
Two (2) 10/100/1000 LAN with RJ-45 connector (Dual Gigabit Ethernet)
USB port
Seven (7); three (3) USB2 in front and four (4) USB3 in rear
TLA7012 integral controls
Front panel display
Size: 15 in. (38.1 cm) diagonal

Type: Active-matrix color TFT LCD with backlight

ion: 1024×768 

Front panel
General-purpose knob with dedicated hotkeys and knobs for horizontal and vertical scaling and scrolling
Touchscreen
Available with Option 18 
Integrated View (iView™) capability
TLA mainframe configuration requirements
GPIB-iView™ (Opt. 1C)

USB-iView™ (Opt. 2C)

Number of Tektronix oscilloscopes that can be connected to a TLA system
External oscilloscopes supported
More than 100. For a complete listing of current supported oscilloscopes, please visit our website http://www.tek.com/iview.
TLA connections
USB, Trigger In, Trigger Out, Clock Out
Oscilloscope connections
GPIB-iView™ (Opt. 1C)
GPIB, Trigger In, Trigger Out, Clock In (when available)
USB-iView™ (Opt. 2C)
USB Device Port, Trigger In, Trigger Out
Setup
iView™ external oscilloscope wizard automates setup.
Data correlation
After oscilloscope acquisition is complete, the data is automatically transferred to the TLA and time correlated with the TLA acquisition data.
Deskew
The oscilloscope and TLA data is automatically deskewed and time correlated when using the iView™ external oscilloscope cable.
GPIB-iView™ (Opt. 1C) External oscilloscope cable length
2 m (6.6 ft.)
USB-iView™ (Opt. 2C) External oscilloscope cable length
2 m (6 ft.)
Symbolic support
Number of symbols/ranges
Unlimited (limited only by amount of virtual memory available on TLA)
Object file formats supported
IEEE695, OMF 51, OMF 86, OMF 166, OMF 286, OMF 386, COFF, Elf/Dwarf 1 and 2, Elf/Stabs, TSF (If your software development tools do not generate output in one of the above formats, TSF, or the Tektronix symbol file, a generic ASCII file format is supported. The generic ASCII file format is documented in the TLA online help). If a format is not listed, please contact your local Tektronix representative.
External instrumentation interface
System Trigger output
Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ω)
System Trigger input
Forces a system trigger when asserted (adjustable threshold between 0.5 V and 1.5 V, edge sensitive, falling-edge latched)
External Signal output
Can be used to drive external circuitry from a module's trigger mechanism (TTL-compatible output, back-terminated into 50 Ω)
External Signal input
Can be used to provide an external signal to arm or trigger any or all modules (adjustable threshold between 0.5 V and 1.5 V, level sensitive)
Power
Power
Voltage range/frequency
90-250 V AC at 45-66 Hz

100-132 V AC at 360-440 Hz

Input current
7 A maximum at 90 V AC (70 A surge)
Power consumption
750 W maximum
TLA7016 Voltage range/frequency
Ratings apply to mainframes with serial numbers B020000 and higher.
Configuration A, Maximum load 1000 W

100 Vrmsto 120 Vrms, 50 Hz to 60 Hz and 115rms, 400 Hz, 1450 W maximum

Configuration B, Maximum load 1000 W
120 Vrms to 240 Vrms, 50 Hz to 60 Hz, 1900 W maximum
TL708EX
Voltage range/frequency
100-240 V AC at 50-60 Hz
Input current
2 A maximum at 100 V AC
Power consumption
200 W maximum
Environmental
Temperature
Operating
+5 °C to +45 °C
Nonoperating
-20 °C to +60 °C
Humidity
20% to 80%
Operating
≤30 °C; 80% relative humidity (29 °C maximum wet-bulb temperature)
Nonoperating
8% to 80% (29 °C maximum wet-bulb temperature)
Altitude
Operating: -1,000 ft. to 10,000 ft. (-305 meters to 3,050 meters)
Safety
UL3111-1, CSA1010.1, EN61010-1, IEC61010-1 
TLA7012 Portable Mainframe physical specifications
Dimensions
Height
295 mm (11.6 in.)
Width
451 mm (17.75 in.)
Depth
460 mm (18.1 in.)
Weight
Net (without modules)
14 kg (30 lb.)
Shipping (typical)
27 kg (59 lb.)
TLA7016 Benchtop Mainframe physical specifications
Dimensions
Height
350 mm (13.7 in.)
Width
425 mm (16.7 in.)
Depth
673 mm (26.5 in.)
Weight
Net (without modules)
25 kg (55 lb.)
Shipping (typical
51.8 kg (115 lb.)
TLA708EX 8-port instrument Hub and expander physical specifications
Dimensions
Height
51 mm (2.0 in.)
Width
455 mm (17.5 in.)
Depth
305 mm (12.0 in.)
Weight
Net
3 kg (6 lb.)
Shipping
5 kg (11 lb.)
TLA7BBx logic analyzer module specifications

All specifications are guaranteed unless noted otherwise. All specifications apply to all TLA7BBx models unless noted otherwise.

General specifications
Number of channels
All channels are acquired including clocks
TLA7BB2
68 channels (4 are clock channels)
TLA7BB3
102 channels (4 are clock and 2 are qualifier channels)
TLA7BB4
136 channels (4 are clock and 4 are qualifier channels)
Channel grouping
No limit to number of groups or number of channels per group (all channels can be reused in multiple groups)
Module merging
Up to five 68-channel, 102-channel, or 136-channel modules can be "merged" to make up to a 680-channel module. Merged modules exhibit the same depth as the lesser of the five individual modules.

Word/setup-and-hold/glitch/transition recognizers span all five modules. Range recognizers limited to three-module merge. Only one set of clock connections is required.

Time stamp
54 bits at 20 ps resolution (>4 days duration)
Clocking/Acquisition modes
Asynchronous and synchronous. 20 ps (50 GHz) MagniVu high-speed timing is available simultaneous with all modes
Number of mainframe instrument slots required per TLA series module
Data input with P6800 or P6900 series probes
Capacitive loading
P6900 series
0.5 pF clock/data
P6800 series
<0.7 pF clock/data
P6810 (In group configuration)
1.0 pF
Threshold selection range
From -2.0 V to +4.5 V in 5 mV increments

Threshold presets include TTL (1.5 V), CMOS (1.65 V), ECL (-1.3 V), PECL (3.7 V), LVPECL (2.0 V), LVCMOS 1.5 V (0.75 V), LVCMOS 1.8 V (0.9 V), LVCMOS 2.5 V (1.25 V), LVCMOS 3.3 V (1.65 V), LVDS (0 V), and user defined.

Threshold selection channel granularity
Separate selection for each of the clock/qualifier and individual channels.
Threshold accuracy (including probe)
±(35 mV + 1%)
Input voltage range
Operating
2.5 V to 5.0 V
Nondestructive
±15 V
Minimum Input Signal Swing
Single-ended
200 mV
Differential
VMAX – VMIN > 100 mV
Input signal minimum slew rate
200 mV/ns typical
State acquisition with P6800 or P6900 series probes
Channel configurations
Configuration Full channel Half channel
750 MHz Standard 750 MHz / 750 Mb/s (1 sample/clock) 750 MHz / 1.5 Gb/s (2 samples/clock) 750 MHz / 3 Gb/s (4 samples/clock)
1.4 GHz Optional 1.4 GHz / 1.4 Gb/s (1 sample/clock) 1.4 GHz / 2.8 Gb/s (2 samples/clock)
State record length with Time stamps
(Quarter/Half/Full channels) 4/2 Mb, 8/4 Mb, 16/8 Mb, 32/16 Mb, 64/32 Mb, 128/64 Mb per channel
Setup and Hold time selection range
From 15 ns before, to 7.5 ns after clock edge in 20 ps increments. Range may be shifted towards the setup region by 0 ns [+7.5, -7.5] ns, 2.5 ns [+10, -5] ns, or 7.5 ns [+15, 0] ns.
Setup and Hold window, single channel
180 ps typical
Minimum clock pulse width
200 ps (P6960, P6962, P6964, P6980, P6982, P6860), 250 ps (P6910)
Demux channel selection
Channels can be demultiplexed to other channels through user interface with 8-channel granularity.
Timing acquisition (with P6800 or P6900 probes)
MagniVu™ timing
20 ps max, adjustments to 40 ps, 80 ps, 160 ps, 320 ps, and 640 ps
MagniVu timing record length
128 Kb per channel, with adjustable trigger position
Deep timing resolution
(Quarter/Half/Full channels)

1.25 ps / 312.5 ps / 625 ps to 50 ms

Deep timing resolution with glitch storage enabled
1.25 ns to 50 ms
Deep timing record length
(Quarter/Half/Full channels)

8/4/2 Mb, 16/8/4 Mb, 32/16/8 Mb, 64/32/16 Mb, 128/64/32 Mb, 256/128/64 Mb per channel

Deep timing record length with glitch storage enabled
Half of default main memory depth
Channel-to-channel skew
(Module + probe)
Before customer deskew
±80 ps typical
After customer deskew
±20 ps typical
Minimum recognizable pulse/glitch width (single channel)
200 ps (P6960, P6962, P6964, P6980, P6982, P6860)

250 ps (P6910)

Minimum detectable Setup/Hold violation
40 ps
Minimum recognizable multichannel Trigger event
Sample period + channel-to-channel skew
Analog acquisition (with P6800 or P6900 probes)
Bandwidth
3 HGz typical
Attenuation
10X, ±1%
Offset and gain (Accuracy)
±50 mV, ±2% of signal amplitude
Channels demultiplexed
Run/Stop requirements
None, analog outputs are always active
iCapture™ Analog outputs
Compatible with any supported Tektronix oscilloscope
iCapture Analog output BNC cables
Four (4) low loss, 10X, 36 in.
Trigger system
Independent Trigger states
16 
Maximum idependent If/Then clauses per state
16 
Maximum numger of events per If/Then clause
Maximum number of actions per If/Then clause
Maximum number of Trigger events
26 (2 counters/timers plus any 24 other resources)
Number of word recognizers
24 
Number of transition recognizers
24 
Number of range recognizers
Number of counters/timers
 
Trigger event types
Word, Group, Channel, Transition, Range, Anything, Counter Value, Timer Value, Signal, Glitch, Setup-and-Hold Violation, Snapshot
Trigger action types
Trigger Module, Trigger All Modules, Trigger Main, Trigger MagniVu, Store, Don't Store, Store Sample, Increment Counter, Decrement Counter, Reset Counter, Start Timer, Stop Timer, Reset Timer, Snapshot Current Sample, Goto State, Set/Clear Signal, Do Nothing
Maximum triggerable data rate
3.0 Gb/s
Trigger machine sequence rate
DC to 800 MHz (1.25 ns)
Counter/timer range
48 bits each (~4 days at 1.25 ns)
Counter rate
DC to 800 MHz (1.25 ns)
Timer clock rate
800 MHz (1.25 ns)
Counter/timer test latency
0 ns
Range recognizers
Double bounded (408 channel maximum). Can be as wide as any group, must be grouped according to specified order of significance.
Setup-and-hold violation recognizer setup time range
From 7.5 ns before, to 7.5 ns after clock edge in 20 ps increments. This range may be shifted toward the positive region by 0 ns, 2.5 ns, 5 ns, or 7.5 ns.
Setup-and-hold violation recognizer hold time range
From 7.5 ns before, to 7.5 ns after clock edge in 20 ps increments. This range may be shifted toward the positive region by 0 ns, 2.5 ns, 5 ns, or 7.5 ns.
Trigger position
Any data sample
MagniVu trigger postion
MagniVu position can be set from 0% to 60% centered around the MagniVu trigger
Storage control (data qualification)
Global (conditional), by state (start/stop), block, by trigger action, or transitional. Also force main prefill selection available.
Physical characteristics
Dimensions
Height
262 mm (10.3 in.)
Width
61 mm (2.4 in.)
Depth
381 mm (15.0 in.)
Weight
Net
3.1 kg (6.7 lb.)
Shipping
6.3 kg (13.7 lb.)