Clock Recovery Module for OI2125 O/E Receiver
OM1420
泰克对于本技术资料上的产品不再有售。
查看 Tektronix Encore 了解翻新测试设备。
查看这些产品的支持和保修状态。
Features & Benefits
- Supports Multiple Data Rates up to 10.664 Gb/s: OC-192/STM-64 (9.953 Gb/s) and OC-192 FEC (10.664 Gb/s)
- Increases Capability of the OI2125 O/E Receiver by Adding Clock Recovery
- Easily Installed Modules
Applications
- Bit Error Rate Testing
- Optical Component and Fiber Loop Testing
- Optical Transmitter Testing
High-performance OM1420 Module Adds Clock Recovery to the OI2125 O/E Receiver up to 10.664 Gb/s (OC-192/STM-64 FEC)
The Tektronix OI2125 O/E Receiver receives modulated optical signals up to 12.5 Gb/s and converts them to electrical signals for further testing with an instrument such as a BER (bit error rate) analyzer. The user-installable OM1420 OC-192 Dual-rate Clock Recovery Module extracts the clock for both OC-192 9.953 Gb/s and OC-192 FEC 10.664 Gb/s rates. The recovered clock signal can then be used to trigger a CSA8000 sampling oscilloscope or be used as the clock input to an error analyzer.
Characteristics
OM1420 OC-192/STM-64 Clock Recovery Module
Specification |
Min |
Typ |
Max |
Units |
Comments |
---|---|---|---|---|---|
Clock Recover Data Rate |
|
9.953280 10.66423 |
|
Gb/s Gb/s |
Switchable |
Jitter Generation |
|
|
2 |
psRMS |
|
Clock Bandwidth |
|
|
10 |
MHz |
|
Input Amplitude |
0.15 |
|
0.75 |
Vp-p |
|
Clock Output Amplitude |
1.0 |
|
2.0 |
Vp-p |
|
Environment
Temperature -
Operating: 0 °C to +40 °C.
Nonoperating: -40 °C to +71 °C.
Humidity -
Operating: 5% to 95% RH (up to +30 °C).
5% to 45% RH (30 °C to +50 °C).
Nonoperating: 5% to 95% RH (up to +30 °C).
5% to 45% RH (30 °C to +50 °C).
Altitude -
Operating: Up to 3000 m (10,000 ft.).
Nonoperating: Up to 12,000 m (40,000 ft.).
EMC Compliance - Meets or exceeds EN55011 Class A Radiated and Conducted Emissions; FCC47 CFR, Part 15, Subpart B, Class A.
Safety - EN61010-1; IEC61010-1.
I/O Interface
OM1420 OC-192 Clock Recovery Module -
Data In (Electrical SMA).
Clock Out (Electrical SMA).
Physical Characteristics
Shipping Weight with Packaging
Instrument/Module |
kg |
lbs. |
---|---|---|
OI1125 |
5.12 |
11.39 |
OI2125 |
5.49 |
12.22 |
OM1420 |
3.76 |
8.39 |
Ordering Information
OM1420
OC-192 Clock Recovery Module
Service
Opt. C3 - Calibration Service 3 Years
Opt. C5 - Calibration Service 5 Years
Opt. D1 - Calibration Data Report
Opt. D3 - Calibration Data Report 3 Years (with Option C3)
Opt. D5 - Calibration Data Report 5 Years (with Option C5)
Opt. R3 - Repair Service 3 Years
Opt. R5 - Repair Service 5 Years
Included Accessories - OM1420
071-1055-00 - User Reference: English only.
006-8018-01 - Important Documents Folder.
Certificate of Calibration: NIST, MIL-STD-45662A and ISO Calibration Certificate.
Placed inside "Important Documents Folder."
174-4699-00 - Cable, RF, Semi-rigid Jumper.
015-1022-01 - Terminator (2 each).
015-0561-00 - Electrical Cable, SMA (1 m long).