联系我们

与泰克代表实时聊天。 工作时间:上午 9:00 - 下午 5:00(太平洋标准时间)。

电话

致电我们

工作时间:上午9:00-下午5:00(太平洋标准时间)

下载

下载手册、产品技术资料、软件等:

下载类型
型号或关键字

反馈

Clock Recovery Module for OI2125 O/E Receiver

OM1420

泰克对于本技术资料上的产品不再有售。
查看 Tektronix Encore 了解翻新测试设备。
查看这些产品的支持保修状态

Features & Benefits

  • Supports Multiple Data Rates up to 10.664 Gb/s: OC-192/STM-64 (9.953 Gb/s) and OC-192 FEC (10.664 Gb/s)
  • Increases Capability of the OI2125 O/E Receiver by Adding Clock Recovery
  • Easily Installed Modules

Applications

  • Bit Error Rate Testing
  • Optical Component and Fiber Loop Testing
  • Optical Transmitter Testing

High-performance OM1420 Module Adds Clock Recovery to the OI2125 O/E Receiver up to 10.664 Gb/s (OC-192/STM-64 FEC)

The Tektronix OI2125 O/E Receiver receives modulated optical signals up to 12.5 Gb/s and converts them to electrical signals for further testing with an instrument such as a BER (bit error rate) analyzer. The user-installable OM1420 OC-192 Dual-rate Clock Recovery Module extracts the clock for both OC-192 9.953 Gb/s and OC-192 FEC 10.664 Gb/s rates. The recovered clock signal can then be used to trigger a CSA8000 sampling oscilloscope or be used as the clock input to an error analyzer.

Characteristics

OM1420 OC-192/STM-64 Clock Recovery Module

Specification

Min

Typ

Max

Units

Comments

Clock Recover Data Rate

   

9.953280 10.66423

   

Gb/s Gb/s

Switchable

Jitter Generation

   

   

2

psRMS

   

Clock Bandwidth

   

   

10

MHz

   

Input Amplitude

0.15

   

0.75

Vp-p

   

Clock Output Amplitude

1.0

   

2.0

Vp-p

   

Environment

Temperature -

Operating: 0 °C to +40 °C.

Nonoperating: -40 °C to +71 °C.

 

Humidity -

Operating: 5% to 95% RH (up to +30 °C).

   5% to 45% RH (30 °C to +50 °C).

Nonoperating: 5% to 95% RH (up to +30 °C).

   5% to 45% RH (30 °C to +50 °C).

 

Altitude -

Operating: Up to 3000 m (10,000 ft.).

Nonoperating: Up to 12,000 m (40,000 ft.).

 

EMC Compliance - Meets or exceeds EN55011 Class A Radiated and Conducted Emissions; FCC47 CFR, Part 15, Subpart B, Class A.

Safety - EN61010-1; IEC61010-1.

I/O Interface

OM1420 OC-192 Clock Recovery Module -

Data In (Electrical SMA).

Clock Out (Electrical SMA).

 

Physical Characteristics

Shipping Weight with Packaging

Instrument/Module

kg

lbs.

OI1125

5.12

11.39

OI2125

5.49

12.22

OM1420

3.76

8.39

Ordering Information

OM1420

OC-192 Clock Recovery Module

Service

Opt. C3 - Calibration Service 3 Years

Opt. C5 - Calibration Service 5 Years

Opt. D1 - Calibration Data Report

Opt. D3 - Calibration Data Report 3 Years (with Option C3)

Opt. D5 - Calibration Data Report 5 Years (with Option C5)

Opt. R3 - Repair Service 3 Years

Opt. R5 - Repair Service 5 Years

Included Accessories - OM1420

071-1055-00 - User Reference: English only.

006-8018-01 - Important Documents Folder.

Certificate of Calibration: NIST, MIL-STD-45662A and ISO Calibration Certificate.

Placed inside "Important Documents Folder."

 

174-4699-00 - Cable, RF, Semi-rigid Jumper.

015-1022-01 - Terminator (2 each).

015-0561-00 - Electrical Cable, SMA (1 m long).